Configure Minimum Configuration
Explanation
This activity is used to set the minimum structure as indicated by the
defined minimum configuration.
The minimum configuration is important for the building of a template
structure. Through the minimum configuration you can specify the minimum
structure that can be set operational. Consequently, when you disconnect a part
that is included in the minimum configuration, the structure (vehicle) will
not be operational. If however you are required to disconnect a minimum
configuration part from the structure, you need to replace it with another part
before the structure can be made operational.
Note that minimum configured parts in the structure of non-serialized parts
will not affect the operational status of corresponding serials structures. Only
the first level of non-serialized parts are considered in serials structures.
Prerequisites
- The top part in the new structure must be defined before an import or copy
can be performed.
- A sub-part in the structure can only be included in the minimum
configuration if its higher assembly is part of the minimum configuration
- To include a sub part in the minimum configuration, the parent part must
be part of the minimum configuration, if the parent part is not configured
in a separate template.
System Effects
As a result of this activity, you will not be able to set the serial structure
operational if one or more parts which are included in the minimum configuration
of the template structure are disconnected.
Window
Serial
Structure Template
Template
Structure Navigator
Related Window Descriptions
Serial Structure
Template/Consist Of
Serial Structure Template/Multilevel
Template Structure
Navigator/Consist Of
Procedure
- Open the
Serial Structure Template or the
Template
Structure Navigator window.
- In the Part Number field, query (F3) for your template structure.
- Click the
Consist Of tab. The Minimum Configuration
check box will be selected for the parts that are included in the minimum
configuration of your structure.
- If you need to move down the structure, select the row that contains the
part, right-click, and then click Next Level until the required parts
are displayed in the table of the tab.
Alternatively, you can choose to perform this procedure by using the
Serial Structure Template/Multilevel tab.
- To unassign a part from the minimum configuration, clear the Minimum
Configuration check box for this part record or right-click and then click Reverse Minimum Config to automatically
clear the check box.
- To assign a part to the minimum configuration,
select the Minimum Configuration check box for this part record or
right-click and then click Reverse Minimum Config to automatically
select the check box.
- Save the record (F12).